Re: (PM) PM3 Missing serial Port

Don Knott (dknott@treco.net)
Thu, 11 Jun 1998 08:50:41 -0400 (EDT)

On Thu, 11 Jun 1998, Thomas C Kinnen wrote:

> >I noticed something strange on a PM3 the other day. When I do a "sh ses"
> >command, all ports except S23 show up with their current status. If I do a
> >"sh s23" for more detail I get this:
>
>
> PRI or CT1? Pri only has 23B+1D so you get S0-S22 on line 0 and S24-S6 on
> line 1. If you have CT1 ytou have S0-S23 on line 0 and S24-S47 on line 1.
> On both you have C0 on the Serial port.
>
> Tom

We are using a PRI and I was wondering about whether it was tied to that
somehow since it did fall right on where the breakpoint would be between
the lines.

Thanks for the reply, I'll call Livingston back and close out my ticket.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Don Knott, Treasure Coast Internet - http://www.treco.net
759 S Federal Highway - Suite 316 - Stuart, FL 34994-2923
Stuart: 286-6998 Ft. Pierce: 879-6177 Fax: 286-7089
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.
Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>