Re: (PM) Bi polar violations?

Kyle Platts (kwplat1@uswest.com)
Tue, 26 May 1998 09:56:29 -0500

tracy@cet-technology.com wrote:
>
> I have a PM-3 set with
> Line0 T 1 inband DS0
> status: UP Framing: D4 Encoding: B8ZS PCM: u-law
> Signaling: FXS loop start
>
> Receive Level: -7.5 DB to -15 DB

You should not use D4 framing with B8ZS encoding. With D4 framing, you
should never invoke the B8ZS.


>
> alarms and violations all 0 except Bipolar ?
> is this a problem? and if so any advice on the issue??
> thanks
>
> Tracy Wheatley
> CET Technology Inc.
>
> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-users' in the body of the message.
> Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>

-- 
Kyle Platts
Network Engineer
!NTERPRISE Networking Services
U S WEST Communications
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.