(PM) Pipeline 50 to PM3

Alexander Morales (alexm@insc.net)
Tue, 12 May 1998 12:57:02 -0400

I cant for the life of me figure out why I cant get an ascend p50 to
connect to my pm3 with more than one channel. I have it set to MP and not
MPP, version is 6.02. Let me post the debug info.

Here is the radius entry

customer Password = "password"
Port-Limit = 2,
Idle-Timeout = 0,
Session-Timeout = 0,
Framed-Address = 209.4.50.113,
Framed-Route = "209.4.50.112/28 209.4.50.113 1"

Here is the ascend debug info

L: CALL CLEARED WITH CAUSE: 16 B1 #9088445
NL: CALL REQUEST: 64K, #9088445
NL: CALL CLEARED WITH CAUSE: 34 #9088445
NL: CALL REQUEST: 64K, #9088445
NL: CALL REQUEST: 64K, #9088445
NL: CLEAR REQUEST: B2
NL: CALL CLEARED WITH CAUSE: 16 B2 #908844

Here is the PM debug info

m3-1> reset s7
Resetting port S7
pm3-1> S7: Sending Disconnect Request
S7: Received Clear Conf (B8 ID:1c)
S7: Sending Request Connect - 64Kbps / Data (B8 ID:1e)
S7: Received Connect - B8
S8: Sending Request Connect - 64Kbps / Data (B9 ID:1f)
S8: Received Connect - B9
S8: Received Disconnect Normal Clearing (B9 ID:1f)
S8: Sending Disconnect Request
S8: Received Clear Conf (B9 ID:1f)

Any Ideas???

Integrated Network Solutions Corp. www.insc.net
305.436.0910 admin@insc.net Serving South Florida
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.