Re: (PM) PipeLine 50/75 to PM3

Tom T. Thai (tomthai@future.net)
Wed, 6 May 1998 17:41:04 -0500 (CDT)

If the user is a location, make sure to enable multilink, if a radius
entry, use Port-Limit = 2.

On Wed, 6 May 1998, Scott Lagos wrote:

> We are trying to assist a client in connecting to our PM3 ComOS 3.8b15,
> dual CT1 with two B channels for a 112K.
>
> We have another client using a 3Com and then are getting the connection on
> two channels fine. We cannot seem to get this PipeLine user to connect
> with more than one channel.
>
> Under the Connection profile we have made sure that ENCAPS is MPP and the
> endcap options are set for Base=2, Min=2 and Max=2.
>
> We have also made sure that the RADIUS profile for this user is the same as
> the user using the 3COM/USR.
>
> I thought I had seen references to this issue in previous threads but did
> not see them on Livingstons site.
>
> Any help would be appreciated.
>
> Thanks in advance.
> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-users' in the body of the message.
> Searchable list archive: <URL:http://www.livingston.com/Tech/archive/>
>

.............. ....................................
Thomas T. Thai Infomedia Interactive Communications
tom@iic.net TEL 612.376.9090 * FAX 612.376.9087

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.