Closer than last time someone asked - it is still in the lab though, but
further along. I think it is working for certain switch types last I heard.
>shouldnt i be able to gain 15 64k channels with 16 commservers with nfas
>functionality?
Only if it were MUTLICHASSIS NFAS - NFAS is normally per chassis. Also,
you'd be crazy to run it that way. You should have a primary D and
secondary D, so you could gain 14 B channels with 16 PRIs.
I think the MAX for one NFAS group is 20 PRIs.
-MZ
-- Lucent Remote Access Division - Chair, Department of Interstitial Affairs Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com For support requests: support@livingston.com <http://www.livingston.com/> Snail mail: 4464 Willow Road, Pleasanton, CA 94588 - To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message.