Re: (PM) USR X2 connecting to Microcom ISPorte & PM2

Nick Rogness (nick@rapidnet.com)
Tue, 10 Feb 1998 15:06:21 -0700 (MST)

On Tue, 10 Feb 1998, Zak Wolfinger wrote:

> I have had several complaints from customers with USR X2
> modems. They connect to our Microcom ISPortes (33.6K -
> analog only) running on Livingston PM2Es. Once they
> connect, they don't seem to be routing (can't ping, etc).
> However I have checked all the settings for Dial-up
> Networking, and in the Network CPL on their systems. Have
> even uninstalled and re-installed DUN. I'm left to believe
> that it's a modem problem as that is the only common
> component and 2 of the customers just "upgraded" to the
> USR's. Both of those customers had working connections
> before they "upgraded". Other customers calling to the same
> lines work fine. Does anyone have a similar experience with
> this? Is there a different init string I should have the
> customers try?
>
> Zak Wolfinger - zak@cyberlink.com
> Systems Administrator - CyberLink, Inc.
> (219) 235-1400, (219) 674-8279
>

I would suggest trying:

AT&F1&K0&I0S32=32S15=128S27=64S32=34

That is the string USR gave me.

***************************************************************************
Nick Rogness "Professionals are predictable, it's
System Administrator the amateurs that are dangerous"
RapidNet Corporate Services, INC
Rapid City, SD, USA
nick@rapidnet.com
***************************************************************************

>
> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-users' in the body of the message.
>
>

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.