Once upon a time Lance Arbuckle shaped the electrons to say...
>I just logged into our PM3 and our newly installed PRI is now showing "up"
>when I do a show line1. I can't remember what I need to tell the PM to
>get the channels to come up. I've already done a reset d1 but line1 still
>shows no service. Does the box need to be rebooted to see the other PRI ?

1. If you have only one line, use line0 NOT line1. We clock from line0.
2. Sounds like you may have an incorrect ISDN switch type set. The 'up'
on the line means the physical T1 layer is connected, but it doesn't say
anything about the channel signalling.

-MZ

--
Lucent Remote Access Division - Chair, Department of Interstitial Affairs
Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com
For support requests: support@livingston.com  <http://www.livingston.com/> 