pm9> dsct inband 0
1 2
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
------------------------------------------------------
A 0 0 1 1 1 1 1 1 1 1 0 1 1 1 1 1 0 1 1 1 0 0 0 0
B 0 0 1 1 1 1 1 1 1 1 0 1 1 1 1 1 0 1 1 1 0 0 0 0
FSM 1 1 4 4 4 4 4 4 4 4 1 4 4 4 4 4 1 4 4 4 1 1 1 1
pm9> dsct inband 1
1 2
0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
------------------------------------------------------
A 0 1 1 1 1 1 1 0 0 1 0 0 0 1 0 1 1 0 1 0 0 1 1 1
B 0 1 1 1 1 1 1 0 0 1 0 0 0 1 0 1 1 0 1 0 0 1 1 1
FSM 1 4 4 4 4 4 4 1 1 4 1 1 1 4 1 4 4 1 4 1 1 4 4 4
The problem should be on 11 on line 1 and it shows good... right?
Thanks,
Allan
Shawn wrote:
>
> I had this once.... Do a
>
> dsct inband 0
>
> and
>
> dsct inband 1
>
> In my case -
>
> pm3-saco-1> dsct inband 0
> 1 2
> 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3
> ------------------------------------------------------
> A 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
> B 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
> FSM 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
> pm3-saco-1>
>
> Line "0" is in use, and the rest are idle... When I had my problem I saw
> that the A & B were set to 1 and so was FSM... It turned out that one of
> the DS0s were busied out - and the other was skipped.
>
> Let me know if this helps.
>
> At 12:26 AM 1/20/98 -0700, you wrote:
> >I've got one port S34 one one of my PM3s that is not receiving calls.
> >
> >S34 64000 on Login/ IDLE 0 0
> 0
> >
> >The hunt group goes completely full and this line doesn't get any use...
> >
> >These are running over channelized T1s. I have swapped line0 and line1
> and the
> >problem stays at port S34.
> >
> >Any Ideas?
> >
> >COMOS 3.7.2
> >
> >Thanks in advance,
> >Allan
> >-
> >To unsubscribe, email 'majordomo@livingston.com' with
> >'unsubscribe portmaster-users' in the body of the message.
> >
> >
-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.