(PM) Unused channel? (fwd)

MegaZone (megazone@livingston.com)
Sun, 18 Jan 1998 12:43:22 -0800 (PST)

Once upon a time Jukka Pakkanen shaped the electrons to say...
>One of the the ports (S29) in our PM3 looks to be ok, but it is
>never used (Mdm On, Status IDLE, input 0, output 0). We have two E1
>lines and all other ports are working fine.
>
>sh s29 shows everything is ok, just like any other port. Resetting
>the port doesn't help.
>
>Any ideas, broken PM3, bad E1 line?

I've seen this on T1s from time to time. Usually it means the telco made
a mistake and has one of the DS0s busied out or forgot to include it in
the hunt group.

-MZ

--
Lucent Remote Access Division - Chair, Department of Interstitial Affairs
Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com