Matt Brown
PoP Manager
Great Works Internet
"Engineering Internet Excellence"
On Tue, 13 Jan 1998, Eric Calvert wrote:
> I'm still having problems with my PM-3 dropping customers. I'm getting
> nowhere with either Lucington or my local phone company. Each is
> pointing their finger at the other. I'm running a PM-3 with 24 56K
> modems and 1 CT1. It is running 2.7.2. Here is the output of "show
> line1":
>
> ---------------------- line1 - T1 Inband DS0 ---------------
>
> Status: UP Framing: D4 Encoding: AMI PCM: u-law
>
> Signaling: Trunk E&M immediate start
>
> Receive Level: +2dB to -7.5dB
>
> Alarms Violations
> ----------------------------- -----------------------------
> Blue 0 Bipolar 17821655
> Yellow 12686 CRC Errors 3108611
> Receive Carrier Loss 0 Multiframe Sync 3996
> Loss of Sync 484
>
> Why are there so many errors? Is this normal? The system uptime is as
> follows:
>
> Livingston PortMaster PM-3 ComOS 3.7.2
> System uptime is 14 days 1 hours 47 minutes
>
> I've been watching the numbers for the past few minutes, and none of
> them are actively counting up.
>
> --
> Eric Calvert
> Caveland Connection
> http://www.caveland.net
> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-users' in the body of the message.
>
-
To unsubscribe, email 'majordomo@livingston.com' with