Re: (PM) PM3 DSP ADMIN state

Matthew Walker (mwalker@lidcam.com.au)
Fri, 9 Jan 1998 11:15:48 +1100

Web Master <spider@alphanet.net.au> writes:
>Sorry! forgotten the OS is 3.7.1c1/9709251909
>
>Is a special build cannot upgrade to later os unless the guys at LE is
>rebuilding the
>OS for handling the OZ SPC code!

Alex,

3.7.2 includes this code. From the 3.7.2 release notes
<http://www.livingston.com/Tech/Docs/Release/release372.shtml>:

Australian ISDN Support

The command "set isdn-switch ts014" is now available on the PortMaster 3
to support the TS014 ISDN PRI switch used in Australia.

Semipermanent connections (SPCs) are supported for switch type ts014 in
Australia. To set up a SPC with switch-type ts014, set the port type
to network hardwired and set the directory number for the port to the
SPC ID, and then reset the port.

>Any solutions, except to rip out the card and re-insert it again!

set mX on for each ADMIN state modem.

upgrade to 3.7.2

Regards

Matthew Walker

Matthew Walker <mailto:mwalker@lidcam.com.au> Lidcam Technology
Ph: +61 3 9820 9077 Level 5 499 St Kilda Rd
Fax: +61 3 9866 1245 Melbourne VIC 3004
<http://www.lidcam.com.au/> AUSTRALIA

-