Re: (PM) Anyone using NT Mulitlink?

Tom (tom@sdf.com)
Wed, 26 Nov 1997 20:42:35 -0800 (PST)

On Wed, 26 Nov 1997, Philip Michael Blancett wrote:

> Hello All,
> I was wondering if anyone had any
> success with ISDN, PM3's and multilink. I
> am trying to set up a NT Box with 2 ISDN
> TA's to connect at a 256K connection. Any
> insight would be appreciated...Thx

That should be possible, but probably not with the equipment you have.

You don't mention the TA type, but most TAs except to take a standard
PPP connection and convert it to MP internally. They do not except to see
one half of a MP session, and spread it over two channels.

It is all about where the MP is being done. In your case, you are
trying to do MP in the TA, and within Windows NT. You can't do that. You
have to do all the MP within Windows NT by using TAs with two serial
ports, and the appropiate hardware on the NT side.

> -
> To unsubscribe, email 'majordomo@livingston.com' with
> 'unsubscribe portmaster-users' in the body of the message.
>
>

Tom

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.