Re: (PM) PRI & CT1 on same PM3 (fwd)

Tim Flavin (tim@i1.net)
Wed, 19 Nov 1997 05:44:18 -0600 (CST)

On Tue, 18 Nov 1997, Jake Messinger wrote:

> On Tue, 18 Nov 1997, Tim Flavin wrote:
>
> > With my question now answered, the only thing you can not do that I've
> > already submitted a week or two ago to rfe@ is mix PRI switch types on the
> > same box. And yes, I do have a use for this.
>
> Right! I remember you asking that Tim. It wasnt the same thing I needed.
> But why do you need 2 switch types? Are you feeding a pm 3 from 2
> different phone co's, 1 giving you b8zs and the other ami/d4?
>

Yes, from 2 different telco's, but you can do b8zs and ami on the same
box, what I need is NI-2 and DMS-100 on the same box which you cannot do.
So my work around is to take service from a 3rd telco, and take it as CT1
so I don't have half a PM3 sitting there idle for a long time to come.

==============================================================
Tim Flavin Internet Access for St Louis & Chicago
Internet 1st, Inc Toll Free Sales & Support 800-875-3173
http://www.i1.net For more information email info@i1.net
==============================================================

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.