Yes, there are different ways to do an SLC.
I forget the proper terminology. But you have 96 lines. This can be
done with 5 T1s - 4 x 24 for 96, and one backup. If both ends are trunk
side this is a clear digital path.
Or you can do it with 3 T1s - 2 to carry the load and one backup. But
isn't 2 x 24 only 48? Yes - so they MUX the calls. That is very likely
to stop PCM from working.
And if they use a lineside connection anywhere that will also kill PCM.
-MZ
-- Livingston Enterprises - Chair, Department of Interstitial Affairs Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com For support requests: support@livingston.com <http://www.livingston.com/> Snail mail: 4464 Willow Road, Pleasanton, CA 94588 - To unsubscribe, email 'majordomo@livingston.com' with 'unsubscribe portmaster-users' in the body of the message.