Re: (PM) Disappearing Port

John Posa (jposa@livingston.com)
Thu, 13 Nov 1997 21:25:05 -0800

Kevin,

With PRI you get 23 B channels and 1 D channel; therefore
you will only get S0 thru S22 (23 channels) on line0 and
line1 will start at S24. If line1 is also PRI, you will
see S24 thru S46. Hope this helps.

John

At 12:12 AM 11/14/97 -0500, Kevin Blumberg wrote:
>PM-3-2AT with 1 PRI active running COMOS 3.7.2. Whereis S23???????
>
>Livingston PortMaster PM-3 ComOS 3.7.2
>System uptime is 8 days 8 hours 8 minutes
>
>
>S21 64000 on Login/ IDLE 0 196
> 0
>S22 64000 on Login/ IDLE 0 123
> 0
>S24 64000 on Login/ NO-SERVICE 0 0
> 0
>
>M20 READY UNKNWN NONE NONE 0 0 NORMAL
>M21 READY UNKNWN NONE NONE 0 0 NORMAL
>M22 READY UNKNWN NONE NONE 0 0 NORMAL
>M23 READY UNKNWN NONE NONE 0 0 NORMAL
>
>
>PM3-1> show s23
>Error: usage: show S0-S29,P0,all,memory,netconns,netstat,routes
>-
>To unsubscribe, email 'majordomo@livingston.com' with
>'unsubscribe portmaster-users' in the body of the message.
>
>

-
To unsubscribe, email 'majordomo@livingston.com' with
'unsubscribe portmaster-users' in the body of the message.