Re: (PM) (ANNC) ComOS 3.7.2 released for all Portmaster

Chris Britton (brit@labyrinth.net)
Wed, 05 Nov 1997 23:09:51 -0500

> PortMaster 3 Modem Card Software Improvements
>
>The "show modem" command no longer displays nonexistent modems in
>the ADMIN state when 8-modem cards are used. The nonexistent modems may
>show up in the first two minutes after reboot, but will not be displayed
>in normal operation after that.
>
pm3> show mod
Mdm Port Status Speed Compression Protocol Calls Retrain Disconnect
--- ---- ------ ----- ----------- -------- ------ ------- ------------
M0 S0 ACTIVE 31200 V42BIS LAPM 48 0 CIRCUIT DISCONNECT.
M1 S11 ACTIVE 28800 V42BIS LAPM 71 0 CIRCUIT DISCONNECT
M2 S3 ACTIVE 28800 V42BIS LAPM 32 0 CIRCUIT DISCONNECT
M3 S1 ACTIVE 28800 V42BIS LAPM 34 2 CIRCUIT DISCONNECT
M4 S4 ACTIVE 31200 V42BIS LAPM 46 0 LAPM DISCONNECT
M5 S8 ACTIVE 33600 V42BIS LAPM 57 0 CIRCUIT DISCONNECT
M6 S12 ACTIVE 24000 V42BIS LAPM 58 0 CIRCUIT DISCONNECT
M7 S2 ACTIVE 26400 V42BIS LAPM 53 0 LAPM DISCONNECT
M8 S10 ACTIVE 28800 V42BIS LAPM 49 0 CIRCUIT DISCONNECT.
M9 S14 ACTIVE 14400 NONE DIRECT 55 0 CIRCUIT DISCONNECT
M10 S15 ACTIVE 28800 V42BIS LAPM 34 0 CIRCUIT DISCONNECT
M11 S6 ACTIVE 50000 V42BIS LAPM 45 1 LAPM DISCONNECT
M12 S5 ACTIVE 28800 V42BIS LAPM 23 0 CIRCUIT DISCONNECT
M13 S9 ACTIVE 28800 V42BIS LAPM 48 0 LAPM DISCONNECT
M14 S7 ACTIVE 28800 NONE DIRECT 65 0 CIRCUIT DISCONNECT
M15 S20 ACTIVE 28800 V42BIS LAPM 31 0 CIRCUIT DISCONNECT
M16 S16 ACTIVE 28800 V42BIS LAPM 16 0 LAPM DISCONNECT
M17 S13 ACTIVE 26400 V42BIS LAPM 56 0 V.42 FAILURE
M18 S17 ACTIVE 33600 V42BIS LAPM 31 0 CIRCUIT DISCONNECT.
M19 S19 ACTIVE 28800 V42BIS LAPM 46 0 CIRCUIT DISCONNECT
-- Press Return for More --
M20 S21 ACTIVE 33600 V42BIS LAPM 39 0 LOST CARRIER
M21 S18 ACTIVE 28800 V42BIS LAPM 25 1 CIRCUIT DISCONNECT
M22 S25 ACTIVE 31200 V42BIS LAPM 46 2 CIRCUIT DISCONNECT
M23 READY UNKNWN NONE NONE 28 0 CIRCUIT DISCONNECT.
M24 S27 ACTIVE 31200 V42BIS LAPM 32 2 LAPM DISCONNECT
M25 S26 ACTIVE 31200 V42BIS LAPM 34 1 CIRCUIT DISCONNECT
M26 S22 ACTIVE 28800 V42BIS LAPM 40 0 CIRCUIT DISCONNECT.
M27 S28 ACTIVE 33600 V42BIS LAPM 30 0 LAPM DISCONNECT
M28 S29 ACTIVE 28800 V42BIS LAPM 36 0 CIRCUIT DISCONNECT
M29 READY UNKNWN NONE NONE 12 0 CIRCUIT DISCONNECT
M30 S31 ACTIVE 28800 V42BIS LAPM 24 1 CIRCUIT DISCONNECT
M31 S33 ACTIVE 26400 V42BIS LAPM 31 0 CIRCUIT DISCONNECT
M32 S36 ACTIVE 26400 V42BIS LAPM 28 0 LAPM DISCONNECT
M33 S34 ACTIVE 31200 V42BIS LAPM 14 1 NORMAL
M34 S32 ACTIVE 31200 NONE LAPM 27 0 CIRCUIT DISCONNECT
M35 S35 ACTIVE 31200 V42BIS LAPM 28 0 CIRCUIT DISCONNECT
M36 S37 ACTIVE 7200 V42BIS LAPM 23 0 LAPM DISCONNECT
M37 S38 ACTIVE 31200 V42BIS LAPM 21 0 LOST CARRIER
M38 S41 ACTIVE 31200 NONE DIRECT 18 0 NORMAL
M39 S40 ACTIVE 31200 V42BIS LAPM 10 0 CIRCUIT DISCONNECT
-- Press Return for More --
M40 S39 ACTIVE 28800 V42BIS LAPM 15 0 NORMAL
M41 S42 ACTIVE 28800 V42BIS LAPM 22 0 CIRCUIT DISCONNECT
M42 READY UNKNWN NONE NONE 22 0 CIRCUIT DISCONNECT
M43 S44 ACTIVE 28800 V42BIS LAPM 19 0 LAPM DISCONNECT
M44 S45 ACTIVE 24000 V42BIS LAPM 18 0 CIRCUIT DISCONNECT
M45 S46 ACTIVE 28800 V42BIS LAPM 9 0 CIRCUIT DISCONNECT
M46 READY UNKNWN NONE NONE 1 0 NORMAL
M47 READY UNKNWN NONE NONE 0 0 NORMAL
M48 ADMIN UNKNWN NONE NONE 0 0 NORMAL
M49 ADMIN UNKNWN NONE NONE 0 0 NORMAL
pm3> ver
Livingston PortMaster PM-3 ComOS 3.7.2
System uptime is 1 days 4 hours 46 minutes

Since m48 and m49 are "ghost" modems on an eight port card why are they still
showing up if this was fixed? Not that I really care, I'm just curious.
-----------------------------------------------------------------------
Labyrinth Solutions Inc. Chris Britton
Systems Manager P.O. Box 434
brit@labyrinth.net Morgantown, WV 26507

-
To unsubscribe, email 'majordomo@livingston.com' with