Re: 2 questions - pmconsole & radius

John G. Thompson (jgt10@livingston.com)
Thu, 28 Aug 1997 17:08:28 -0700

At 03:01 PM 8/27/97 -0500, Zak Wolfinger wrote:
>I am having the following problems and hoping someone can shed some light
>for me.
>
>1. I am trying to install Livingston's Radius NT 2.0 on my NT 4.0 SP3
>server. When I install the DAO (DOA!) it loads up to 75% and then says
>that the install is complete - no errors or anything. Radius NT sets up
>completely also with no errors.

While disconcerting the 75% is normal.

> When I try to run Radius NT it states that
>it can't start the DAO/Jet engine. I have tried making sure nothing is
>running during the install (No POP,SMTP,Post,Imap,HTTP,FTP, or Cold Fusion
>services are started) but to no avail.

Get the following two files. They should help the above.

ftp://ftp.livingston.com/pub/le/software/pc/mfc24.txt
ftp://ftp.livingston.com/pub/le/software/pc/mfc24.dll

Read the txt files and perform the installs. If the problem persists, call
and open a case with tech support at 800-458-9966.

>
>2. When Running PMConsole in my Win95 (rev B) machine. I can do everything
>except check the network stats. When I try to check the net stats, I get
>the following error:
>
>PMWCONS caused a general protection fault
>in module PMWCONS.EXE at 000c:00002920.
>
>It doesn't matter which PM2E30 or PM3 unit I'm checking, it always crashes.

Hmm. Haven't seen that one. What version of PMconsole are you running?

JGT
---------------------------------------------------------------------------
John G. Thompson Livingston Enterprises Inc. Phone: (800) 458-9966
JOAT(MON) 4464 Willow Road Fax: (510)737-2110
support@livingston.com Pleasanton, CA 94588 http://www.livingston.com/
---------------------------------------------------------------------------