The "Custom" notation probably refers to the switch type. There are
different "flavors" of 5ESS depending on the software they are running on
the switch. Pac Bell is probably running the custom software set. I think
that is the same as what I have down here. You might try setting your
switch type to NI-2. I think the command is:

set isdn-switch ni-2

Don't be afraid to try different settings. It can't hurt anything.

Also, you should check the lights on your smart jack at the telco demarc.
They may have the circuit in a loopback for testing. Sometimes they have
the circuit looped up somewhere waiting for authorization to release the
circuit.

If you don't have a loopback plug for your PRI cables, I would suggest
making one before you call Pac Bell and be ready to put it on the end of
your cable that goes into your line0 or line1 port on your PM3. That way
you can have them run a test on the line to be sure it is in good shape
before you put it in service.

Good luck!

--
Ron Parker
Network Communications Specialist
Brazosport College

On Sun, 17 Aug 1997, Jeff Northon wrote:

> Hi! > > > I am having a problem with our first PM3. There is probably > a setting off somewhere. > > We have Pac Bell PRI, > > features: ESF , B8ZS , AT&T #5 ESS , > > (And from the Pac Bell guy's faxed notes " Need timing (clocking) > from T-1 CKT - not from internal source". > > And the note says - Set for "CUSTOM" > > Err, where do I set that???? > > I think that is what the problem is.. > > ComOS version 3.7 as of last nite. 48 modems, the new ones. > > When I plug the PRI into line0, and then turn the PM3 on there is > a red led by the first port (line0), then a second of red and green, then > the red led is on solid. The manual says the PM3 doesn't understand > the service from Pac Bell, Appendix A, led diagnostics. > > > I have (mis)set the second port (port1) to be a T-1. It shows up as W24. > > Anyone want to show me my error? > > Thanks, > > Jeff Northon > jeffo@sasquatch.com > 408 336-3391 > > > > > Console log is featured below. > > > PortMaster Console login: !root > Password: > ts-001> version > Livingston PortMaster PM-3 ComOS 3.7 > System uptime is 2 minutes > ts-001> show line0 > ---------------------- line0 - T1 Primary Rate ISDN --------------- > > Status: DOWN Framing: ESF Encoding: B8ZS PCM: u-law > > Receive Level: +2dB to -7.5dB > > Alarms Violations > ----------------------------- ----------------------------- > *Blue 1 Bipolar 0 > Yellow 0 CRC Errors 0 > Receive Carrier Loss 0 Multiframe Sync 57001 > *Loss of Sync 1 > > > > ts-001> show all > Local Addr: 165.227.66.33 Default Host: 0.0.0.0 > Gateway: 165.227.66.1 Netmask: 255.255.255.192 > DNS Server: 165.227.66.1 Domain: sasquatch.com > > Port Speed Mdm Host Type Status Input Output > Pend > ---- ----- --- ---------------- ------ ------------- ---------- ---------- > ---- > C0 9600 off Login COMMAND 123 3865 > 2 > S0 64000 on Login/ NO-SERVICE 0 0 > 0 > S1 64000 on Login/ NO-SERVICE 0 0 > 0 > S2 64000 on Login/ NO-SERVICE 0 0 > 0 > S3 64000 on Login/ NO-SERVICE 0 0 > 0 > S4 64000 on Login/ NO-SERVICE 0 0 > 0 > S5 64000 on Login/ NO-SERVICE 0 0 > 0 > S6 64000 on Login/ NO-SERVICE 0 0 > 0 > S7 64000 on Login/ NO-SERVICE 0 0 > 0 > S8 64000 on Login/ NO-SERVICE 0 0 > 0 > S9 64000 on Login/ NO-SERVICE 0 0 > 0 > S10 64000 on Login/ NO-SERVICE 0 0 > 0 > S11 64000 on Login/ NO-SERVICE 0 0 > 0 > S12 64000 on Login/ NO-SERVICE 0 0 > 0 > S13 64000 on Login/ NO-SERVICE 0 0 > 0 > S14 64000 on Login/ NO-SERVICE 0 0 > 0 > S15 64000 on Login/ NO-SERVICE 0 0 > 0 > -- Press Return for More -- > S16 64000 on Login/ NO-SERVICE 0 0 > 0 > S17 64000 on Login/ NO-SERVICE 0 0 > 0 > S18 64000 on Login/ NO-SERVICE 0 0 > 0 > S19 64000 on Login/ NO-SERVICE 0 0 > 0 > S20 64000 on Login/ NO-SERVICE 0 0 > 0 > S21 64000 on Login/ NO-SERVICE 0 0 > 0 > S22 64000 on Login/ NO-SERVICE 0 0 > 0 > W24 1536K off Netwrk IDLE 0 0 > 0 > ts-001> exit > >