Jason
On Tue, 12 Aug 1997, Jake Messinger wrote:
> On Tue, 12 Aug 1997, Jason Nealis wrote:
>
> >
> >
> > OK, I'm trying to get a Pipe 50 to connect both B1/B2 channels to a PM2er
> > w/ 5port BRI card. Looks like the MAX is dialing channel 1 for both
> > b1 and b2. Am I missing something here.
>
> Where does the max come in?
>
> > #Here you see B1 comming in.
> >
> >
> > S11: Sending Request Connect - 64Kbps / Data (B1 ID:13a)
> > S11: Received Connect - B1
> > Received LCP_CONFIGURE_REQUEST on port S11 of 21 bytes containing:
> > 01 02 00 19 00 04 00 00 01 04 05 f4 11 04 05 f4
> > 13 09 03 00 c0 7b 60 09 41
> > Sending LCP_CONFIGURE_REQUEST to port S11 of 27 bytes containing:
> > 01 02 00 1b 05 06 8c d9 64 7e 03 04 c0 23 11 04
> > 06 1c 13 09 03 00 c0 05 01 72 8f
> > Sending LCP_CONFIGURE_REJECT to port S11 of 8 bytes containing:
> > 04 02 00 08 00 04 00 00
> > Received LCP_CONFIGURE_ACK on port S11 of 23 bytes containing:
> > 02 02 00 1b 05 06 8c d9 64 7e 03 04 c0 23 11 04
> > 06 1c 13 09 03 00 c0 05 01 72 8f
> > Sending IPCP_CONFIGURE_REJECT to port S11 of 22 bytes containing:
> > 04 01 00 16 82 06 00 00 00 00 83 06 00 00 00 00
> > 84 06 00 00 00 00
> > Received IPCP_CONFIGURE_NAK on port S11 of 6 bytes containing:
> > 03 01 00 0a 02 06 00 2d 05 01
> > Sending IPCP_CONFIGURE_REQUEST to port S11 of 10 bytes containing:
> > 01 02 00 0a 03 06 0a 0b 40 f8
> > Received IPCP_CONFIGURE_REQUEST on port S11 of 18 bytes containing:
> > 01 02 00 16 02 06 00 2d 05 01 03 06 cf 60 49 49
> > 81 06 cd fc 74 0a
> > Sending IPCP_CONFIGURE_ACK to port S11 of 22 bytes containing:
> > 02 02 00 16 02 06 00 2d 05 01 03 06 cf 60 49 49
> > 81 06 cd fc 74 0a
> > Received IPCP_CONFIGURE_ACK on port S11 of 6 bytes containing:
> > 02 02 00 0a 03 06 0a 0b 40 f8
> > S11: IPCP Open
> > LCP IPCP Open
> > Connection Succeeded
> >
> > #Here comes B2. But it's rejected with a cause code of 18
> >
> >
> > S10: Sending Request Connect - 64Kbps / Data (B2 ID:13b)
> > S10: Received Disconnect Ack Call Rejected
> > S10: Received Call Clear
> > S10: Sending Request Connect - 64Kbps / Data (B2 ID:13c)
> > S10: Received Disconnect Ack Call Rejected
> > S10: Received Call Clear
> >
> >
> > #as you see here the Max is dialing #1158 for both b1 and b2 instead of
> > dialing #1159 to bring up second channel. Both configured for NI1.
>
> I think you will have to set up 2 locations that are just slightly
> different so the pipe 50 thinks its 2 different locations. Make them the
> same fone # tho and the same ip address.
>
> BTW, do you mean to be saying MAX, or pipe 50?
>
> ~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~
> Jake Messinger 713-772-6690 jake@ams.com
> Advanced Medical Systems, Inc. jake@uh.edu
> 8300 Bissonnet #400
> Houston, Texas 77074 http://www.ams.com/~jake
> ~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~'`^`'~*-,._.,-*~
>