On Sun, 10 Aug 1997, Miguel Correia Lima wrote:
> Hi Jack,
>
> Thanks by your replay.
>
> On Sun, 10 Aug 1997, Jake Messinger wrote:
> > On Sat, 9 Aug 1997, Miguel Correia Lima wrote:
> > > When I purchase the last expantion (3o card) of PM2-eR
> > > only the first 20 ports complitely a ppp negociation, the
> > > last 10 ports receice a call, connect, radius delivery
> > > autorization, but the connection do not estabilished,
> > > pmconsole show CONNECTING continuos.....
> >
> > Open the box and check the REVISION on the 10 port card. Look on or near
> > the tag with the bar code on it. It should be revision B or C. A will not
> > work in a 2eR.
>
> OK! 400-1240 Rev B!
>
> > Also check to make sure the dual jumpers are in the right location.
> +---+ midles jumpers closed with 2 jumpers.
> o|o o|
> o|o o|
> +---+
> 1 2
>
> --------------------------------
> Miguel Correia Lima - Tech. Dep.
> Triangulo Internet Provider
> Fone/Fax: +55-34-216-4251
> E-mail:miguel@triang.com.br
> --------------------------------
>