Re: errors

Wayne Bouchard (web@typo.org)
Thu, 7 Aug 1997 13:41:49 -0700 (MST)

set line0 loopback

should accomplish the desired effect.. But I wouldn't mind an explicit
"shutdown" command.

>
> which brings to mind...
>
> do the pm3 have an interface shutdown command for unused interfaces? :)
>
> On Thu, 7 Aug 1997, Kyle Platts wrote:
>
> >
> > >A dont use line 1 as of yet but I did a show lin1 and it has these errors.
> > Are these normal since it is not beinig used?
> >
> > >Alarms Violations
> > ----------------------------- -----------------------------
> > > Blue 0 Bipolar 2265648434
> > Yellow 0 CRC Errors 0
> > *Receive Carrier Loss 1 Multiframe Sync 398944827
> > *Loss of Sync 1
> > >Integrated Network Solutions Corp. www.insc.net
> > 305.436.0910 admin@insc.net Serving South Florida
> >
> > Any T-1 not in use should have a loop plug in it. This keeps equipment from dealing with alarms all the time due to a span that is not in use.
> >
> > Kyle Platts
> > CSS-Tech
> > !NTERPRISE Networking Services
> >
>
> Robert H. Hanson
> 422 West Riverside Cutting Edge Communications, Inc.
> Suite #516
> Spokane, Wa. 99201 Regional Commercial Internet Service Provider
> (509) 444-INET email: roberth@cet.com - http://www.cet.com/
>
>

----------------------------------------------------------------------
Wayne Bouchard GlobalCenter
web@primenet.com
Primenet Network Engineering Internet Solutions for
(602) 416-6422 800-373-2499 x6422 Growing Businesses
FAX: (602) 416-9422
http://www.primenet.com http://www.globalcenter.net
----------------------------------------------------------------------