RadiusNT 2.0 Problems (fwd)

MegaZone (megazone@livingston.com)
Fri, 11 Jul 1997 15:35:49 -0700 (PDT)

Once upon a time Ed Courtenay shaped the electrons to say...
>I returned immediately to find that the RadiusNT service had stopped, so I
>went to restart it and got error messages saying that it couldn't open
>DAO/Jet. I re-installed DAO, no joy, removed DAO and reinstalled, no joy,
>even removed DAO and Radius and installed both of them, but still no joy.
>
>In the end, I dug out my copy of Microsoft Office 97 (which was not
>installed on that machine) and installed the Data Access modules from the
>CD, and voila, it worked!

I have no idea... Weird. I'll pass it to the support group as a heads up
though.

>As a side issue, looking though my logs for RadiusNT, every login session
>seems to include the following entry:
>
>date/time: [80] received unknown attribute 77

One of the RADIUS attribues - Connect-Info - got renumberd to 77 by the WG
to resolve a conflict between the Extensions Draft and the Tunneling Draft.
I think it used to be 65. You'll need to change the dictionary entry - I
believe the b20 release notes covered this.

-MZ

--
Livingston Enterprises - Chair, Department of Interstitial Affairs
Phone: 800-458-9966 510-737-2100 FAX: 510-737-2110 megazone@livingston.com
For support requests: support@livingston.com  <http://www.livingston.com/> 
Snail mail: 4464 Willow Road, Pleasanton, CA 94588