RE: PM2E Ethernet Interface not seen by hub.....

Shawn Lewis (slewis@thecia.net)
Sat, 9 Nov 1996 07:33:22 -0500

Have you properly changed the DIP switches in the
back. The PM2E's default to COAX, you need to change
the DIPS to make it UTP.

Shawn
---------------------------------------------
Shawn Lewis slewis@thecia.net
Sr Systems Engineer 617.225.4100 x122

Complete Internet Access, Inc
We Give Good Web!!!!
---------------------------------------------

----------
From: Mark Colasante[SMTP:mcola@netexp.net]
Sent: Saturday, November 09, 1996 4:29 AM
To: Portmaster Users List
Subject: PM2E Ethernet Interface not seen by hub.....

We just bought 2 new PM2e units and configured them just like all the
others we have done in the past. The ComOS is 3.3.2 We set up an ip
address and a subnet mask of 255.255.255.0 on each through console
connection through s0, saved the config and restarted them. Next we
plugged them into the hub and neither one shows a valid connection to the
hub. That is we get no light whatsoever on the hub port. We have tried
different hubs and different patch cabling but still the units do not show
valid connections to a hub. We are using 10bT part of the Ethernet
interface.

AM I forgetting something or are these units possibly damaged. I bought
them from the same place about 1 week apart.

Your thoughts are much appreciated.

Mark Colasante
NetExpress, Inc. Phone: (614) 326-6300
5025 Arlington Centre Blvd. Fax: (614) 326-6303
Columbus, OH 43220 Email: mcola@netexp.net
http://www.netexp.net